About: Gastric tonometry     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : yago:Trial105799212, within Data Space : dbpedia.org associated with source document(s)
QRcode icon
http://dbpedia.org/describe/?url=http%3A%2F%2Fdbpedia.org%2Fresource%2FGastric_tonometry

Gastric tonometry describes the measurement of the carbon dioxide level inside the stomach in order to assess the degree of blood flow to the stomach and bowel. Gastric tonometry has been introduced as a novel method of monitoring tissue perfusion in critically ill patients. Tonometry is based on the principle that at equilibrium the partial pressure of a diffusible gas such as CO2 is the same in both the wall and lumen of a viscus. The technique therefore can estimate gut mucosal PCO2 by measuring gut luminal PCO2 at equilibrium. A saline-filled balloon made of CO2 permeable silicone attached to a sampling tube is introduced into the gastric lumen as a nasogastric tube would be. After an equilibration period the fluid is sampled to measure PCO2. Because the mucosal and systemic bicarbonat

AttributesValues
rdf:type
rdfs:label
  • Gastric tonometry (en)
rdfs:comment
  • Gastric tonometry describes the measurement of the carbon dioxide level inside the stomach in order to assess the degree of blood flow to the stomach and bowel. Gastric tonometry has been introduced as a novel method of monitoring tissue perfusion in critically ill patients. Tonometry is based on the principle that at equilibrium the partial pressure of a diffusible gas such as CO2 is the same in both the wall and lumen of a viscus. The technique therefore can estimate gut mucosal PCO2 by measuring gut luminal PCO2 at equilibrium. A saline-filled balloon made of CO2 permeable silicone attached to a sampling tube is introduced into the gastric lumen as a nasogastric tube would be. After an equilibration period the fluid is sampled to measure PCO2. Because the mucosal and systemic bicarbonat (en)
name
  • Gastric tonometry (en)
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
sameAs
dbp:wikiPageUsesTemplate
has abstract
  • Gastric tonometry describes the measurement of the carbon dioxide level inside the stomach in order to assess the degree of blood flow to the stomach and bowel. Gastric tonometry has been introduced as a novel method of monitoring tissue perfusion in critically ill patients. Tonometry is based on the principle that at equilibrium the partial pressure of a diffusible gas such as CO2 is the same in both the wall and lumen of a viscus. The technique therefore can estimate gut mucosal PCO2 by measuring gut luminal PCO2 at equilibrium. A saline-filled balloon made of CO2 permeable silicone attached to a sampling tube is introduced into the gastric lumen as a nasogastric tube would be. After an equilibration period the fluid is sampled to measure PCO2. Because the mucosal and systemic bicarbonate concentrations are equal, a modified Henderson-Hasselbalch equation may be used to calculate the intramucosal pH: pHi = 6.1 + log [HCO3−/0.03 x PCO2]. Thus, only gastric luminal PCO2 is directly measured. Mucosal PCO2 is presumed to be proportional at equilibrium and mucosal pH is calculated. PO2 and luminal pH play no role in these calculations. Proponents of this technique maintain that it is a relatively inexpensive noninvasive, tissue-specific method to evaluate the adequacy of tissue perfusion. It is of special value when used in the gastric lumen because splanchnic circulation is one of the vascular beds that is subject to early blood flow redistribution in shock states. Critics of the technique caution that while directly measured factors are usually accurate and calculated factors correspondingly reliable, the assumption that gut mucosal pH alterations are uniquely a function of mucosal hypoxia is not. Tonometry may adequately reflect the degree of tissue perfusion, but its accuracy as an index of tissue oxygenation is less reliable. The measurement of gut mucosal carbon dioxide has been used to detect decreased blood flow. Accumulation of carbon dioxide is predominantly a result of hypoperfusion and not hypoxia. Because the introduction of a nasogastric tube is almost routine in critically ill patients, the measurement of gastric carbon dioxide can be an easy method to monitor tissue perfusion. The gastric mucosal pH is measured according to an equation that assumes that arterial bicarbonate is equal to intramucosal bicarbonate, an argument that is not always valid. Given that the gastric mucosal carbon dioxide is the directly measured value, whereas the gastric mucosal pH is the derived and possibly inaccurate value, studies that used gastric pH to monitor perfusion may be inherently flawed. Most studies have failed to effectively affect gastric pH and for this reason failed to produce improvements in outcome. One study, by Gutierrez and colleagues, has shown that therapeutic interventions guided by gastric tonometry improved survival in critically ill patients. In a direct comparison of as guided by gastric tonometry with conventional shock management of trauma patients, there was no difference in mortality rates, organ dysfunction rates, or length of stay. After a surge in popularity, the use of gastric tonometry waned and it is currently found with less frequency in surgical ICUs. (en)
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is differentFrom of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (61 GB total memory, 51 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software